Casa Rinconada 29SJ 386 Room: Room 2 Story: 1 Year 1992
Capping Mortars
# of buckets Source Material
Dirt Cans Cups of color
Sand Describe Color:
Clay Duraweld-C (1:4)
Cement Duraweld-C (other)
Comments:
Wall Mortar
# of buckets Source Material
Dirt Duraweld C (1:4)
Sand Duraweld (other)
Clay
Comments:
Walls recorded: North, East, South, West, North
Start: 18/5/1992 End: 27/5/1992 Person Days: 8.0
 
Overall Comments: 1/4.5 Rhoplex/ water 4 parts soil, 2 parts sand, 1 part clay Amended mortar mix, pastelike mixture.



Casa Rinconada 29SJ 386 Room: Room 2 Story: 1 Wall: North Interior Year 1992
Condition
Condition:
Loose wall caps: Light
Stone Erosion: Light
Mortar Erosion: Light
Basal Erosion: Light
Note:
     Light loose or fallen chinking.








Casa Rinconada 29SJ 386 Room: Room 2 Story: 1 Wall: North Interior Year 1992
Treatment
Treatment:
Vertical Wall Repair:
Basal Wall Repair:
Repointing (sq ft): 12.0
Masonry: 12.0
Mortar (# buckets): 1.0
Treatment comment: 15 stones were replaced, unknown how many site or fresh.








Casa Rinconada 29SJ 386 Room: Room 2 Story: 1 Wall: East Interior Year 1992
Condition
Condition:
Loose wall caps: Light
Stone Erosion: Light
Mortar Erosion: Heavy
Basal Erosion: Light
Note:
     Light loose or fallen chinking.








Casa Rinconada 29SJ 386 Room: Room 2 Story: 1 Wall: East Interior Year 1992
Treatment
Treatment:
Vertical Wall Repair:
Basal Wall Repair:
Repointing (sq ft): 2.0
Masonry: 2.0
Stone replaced (#): 4.0
Mortar (# buckets): 0.5
Treatment comment: 4 stones were replaces, unknown how many site or fresh.








Casa Rinconada 29SJ 386 Room: Room 2 Story: 1 Wall: South Interior Year 1992
Condition
Photo type: Before 074_04
Image #: 110947
Catalog #:        Accession #:
Condition:
Loose wall caps: Heavy
Stone Erosion: Heavy
Mortar Erosion: Extreme
Basal Erosion: Heavy
Note:
     Heavy loose or fallen chinking.








Casa Rinconada 29SJ 386 Room: Room 2 Story: 1 Wall: South Interior Year 1992
Treatment
Treatment:
Vertical Wall Repair:
Basal Wall Repair:
Repointing (sq ft): 5.0
Masonry: 5.0
Mortar (# buckets): 0.5
Treatment comment: 36 stones were replaced, number of fresh or site is unknown.








Casa Rinconada 29SJ 386 Room: Room 2 Story: 1 Wall: West Interior Year 1992
Condition
Photo type: Before 074_06
Image #: 110949
Catalog #:        Accession #:
Condition:
Loose wall caps: Light
Stone Erosion: Light
Mortar Erosion: Heavy
Basal Erosion: Light
Note:
     Light loose or fallen chinking.








Casa Rinconada 29SJ 386 Room: Room 2 Story: 1 Wall: West Interior Year 1992
Treatment
Treatment:
Vertical Wall Repair:
Basal Wall Repair:
Repointing (sq ft): 8.0
Masonry: 8.0
Mortar (# buckets): 3.0
Treatment comment: 30 stones replaces, number of site or fresh is unknown.








Casa Rinconada 29SJ 386 Room: Room 2 Story: 1 Wall: North Exterior Year 1992
Condition
Photo type: Before 074_09
Image #: 110952
Catalog #:        Accession #:
Condition:
Mortar Erosion: Heavy
Note:
     Light loose or fallen chinking.








Casa Rinconada 29SJ 386 Room: Room 2 Story: 1 Wall: North Exterior Year 1992
Condition
Photo type: Before 074_10
Image #: 110953
Catalog #:        Accession #:
Condition:
Mortar Erosion: Heavy
Note:
     Light loose or fallen chinking.








Casa Rinconada 29SJ 386 Room: Room 2 Story: 1 Wall: North Exterior Year 1992
Treatment
Treatment:
Vertical Wall Repair:
Repointing (sq ft): 124.0
Masonry: 2.0
Mortar (# buckets): 4.5